Here > Home > Service & Support > Industry Info > Details Page
SECEPOL heat exchanger several technical advantages
Updated:2011-11-09 12:00:00    Copyfrom:sdhuge    Hits: Notice: Undefined index: clicknum in /data/user/htdocs/en/APP/special/view.php on line 72
SECESPOL JAD series of heat exchanger performance description
JAD series of heat exchangers for the EU imported products, is SECESPOL International Group with Poland Gdansk University of Technology Institute of the heat transfer technology and a number of the essence, invented in 1988, the production of a spiral-ribbed tube heat exchanger. Products in strict accordance with American Society of Mechanical Engineers (ASME) standards for manufacturing, is the world's most advanced shell and tube heat exchanger, one compared with the general domestic heat exchanger, JAD heat exchanger has the following advantages:
1, JAD series of heat exchanger, high efficiency, energy efficient, saving energy (steam):
JAD Series heat exchangers heat exchanger than the average domestic condensing water temperature can be controlled at a lower level, to ensure full condensation of steam, the steam consumption savings. Although the JAD compact heat exchanger, but because of its unique spiral winding structure, the steam in the heat exchange bundle to stay longer, condensing more fully, and without going through the secondary heat exchanger, it can save a lot of steam;
2, JAD series of heat exchanger fouling tendency of low and easy to clean:
JAD series of heat exchangers 100 ° connection and screw thread structure, a unique surface treatment technology and media on both sides of the countercurrent heat exchanger to achieve a high flow rate, temperature gradient is small, dirt coefficient characteristics, low fouling tendency.
Even after scaling phenomenon long-term use can also be used quickly descaling chemical cleaning methods, saving time, effort, low cost, good effect.
3, JAD heat exchanger more compact size:
JAD series of heat exchanger size is generally made only with considerable shell and tube heat exchanger volume of about 1 / 5 to save space; but also because of small size, light weight, easier installation, removal and cleaning, reducing installation time and the latter part of maintenance costs;
4, the heat transfer coefficient:
Heat transfer coefficient reflects the level of heat exchanger performance is superior or not, specific conditions, JAD highest heat transfer coefficient can reach 14000w/m2. ℃, heat transfer coefficient is generally made only 2000-3000 w / square meters. ℃ or so, even if the plate heat exchanger applications in the best water - water heat exchanger certain conditions, the heat transfer coefficient is only 5000-7000 w / m. ℃.
5, long service life:
SECESPOL heat exchanger using Owen (OWEN) principle of turbulence buffeting frequency standards, using the minimum clearance Tube bundle design, effectively eliminating the turbulence buffeting phenomenon, extending the life of the heat exchanger. JAD heat exchanger design life of up to 40 years, normal use conditions, the heat exchanger 8 years, the quality problem free repair or replacement, the average domestic heat exchanger can only use about 5 years;
6, is more suitable for high temperature and pressure steam conditions:
JAD heat exchanger temperature, high pressure, due to beam JAD heat exchanger tubes and the shell of stainless steel materials, with uniform coefficient of expansion, not because of pressure and temperature instability of deformation caused by heat; heat device temperature, and elegant, without temperature and pressure reduction devices, saving the cost of initial investment, but also avoiding the vacuum caused by temperature waste heat of steam;
7, JAD heat exchanger, low noise operation:
(Eisnger准则和Bevins准则),有效抑制了声驻波震动现象,最大限度的限制了运行噪音,换热器运行时几乎没有噪音;" closure_uid_4i6xdh="1825" Gf="Designed to take into account the internal structure of the (Eisnger guidelines and Bevins guidelines), effectively inhibited the phenomenon of acoustic standing wave vibration, the maximum limit of operating noise, heat exchangers running almost no noise; " Ff="内部结构设计时考虑了<声共鸣许用准则>(Eisnger准则和Bevins准则),有效抑制了声驻波震动现象,最大限度的限制了运行噪音,换热器运行时几乎没有噪音;">Designed to take into account the internal structure of the <sound resonance allowable criteria> (Eisnger guidelines and Bevins guidelines), effectively inhibited the phenomenon of acoustic standing wave vibration, the maximum limit of operating noise, heat exchangers running almost no noise;
8, JAD heat exchanger by the ASME, ANCC and other eight international quality certification, in Europe known as the "Prince of steam."

JAD-made shell and tube heat exchanger and heat exchanger performance comparison
1, JAD heat exchanger, high efficiency, energy efficient, saving energy (steam):
JAD heat exchanger than the average domestic water heat exchanger condensing temperature can be controlled at a lower level, to ensure full condensation of steam, the steam consumption savings. Although the JAD compact heat exchanger, but because of its unique spiral winding structure, the steam in the heat exchange bundle to stay longer, condensing more fully, and without going through the secondary heat exchanger, it can save a lot of steam;
2, JAD heat exchanger fouling tendency of low and easy to clean:
JAD heat exchanger 100 ° connection and screw thread structure, a unique surface treatment technology and media on both sides of the countercurrent heat exchanger to achieve a high flow rate, temperature gradient is small, dirt coefficient characteristics, low fouling tendency.
Even after scaling phenomenon long-term use can also be used quickly descaling chemical cleaning methods, saving time, effort, low cost, good effect.
By comparison, domestic shell and tube heat exchanger as bulky, relatively coarse shell and tube wall, the fluid flow more moderate, dead too, making the entire heat exchanger fouling tendency greatly increased. After cleaning the heat exchanger fouling problems, due to shell and tube material differences, the general chemical descaling not only by mechanical or manual cleaning, process complexity, high cost; Even if you use chemical cleaning, because their structural characteristics, often makes the cleaning effect is not ideal; and because of large size, is bound to make cleaning time increases, the cost increase;
3, JAD heat exchanger more compact size:
JAD series of heat exchanger size is generally made only with considerable shell and tube heat exchanger volume of about 1 / 5 to save space; but also because of small size, light weight, easier installation, removal and cleaning, reducing installation time and the latter part of maintenance costs;
4, the heat transfer coefficient:
Heat transfer coefficient reflects the level of heat exchanger performance is superior or not, specific conditions, JAD highest heat transfer coefficient can reach 14000w/m2. ℃, heat transfer coefficient is generally made only 2000-3000 w / square meters. ℃ or so, even if the plate heat exchanger applications in the best water - water heat exchanger certain conditions, the heat transfer coefficient is only 5000-7000 w / m. ℃.
5, long service life:
SECESPOL heat exchanger using Owen (OWEN) principle of turbulence buffeting frequency standards, using the minimum clearance Tube bundle design, effectively eliminating the turbulence buffeting phenomenon, extending the life of the heat exchanger. Heat exchanger design life of 40 years, eight years if the normal operation of the heat exchanger in the quality problem, our free repair or replacement, the average domestic heat exchanger can only use about 5 years;
6, is more suitable for high temperature and pressure steam conditions:
JAD heat exchanger up to temperature, pressure, heat exchanger tubes as JAD beam and shell of stainless steel materials, with uniform coefficient of expansion, not because of pressure and temperature instability of deformation caused by heat; heat exchanger temperature, pressure, temperature and pressure reduction devices without the need both to save the initial investment costs, but also avoiding the vacuum caused by temperature waste heat of steam;
7, JAD heat exchanger, low noise operation:
(Eisnger准则和Bevins准则),有效抑制了声驻波震动现象,最大限度的限制了运行噪音,换热器运行时几乎没有噪音;" closure_uid_4i6xdh="1850" Gf="Designed to take into account the internal structure of the (Eisnger guidelines and Bevins guidelines), effectively inhibited the phenomenon of acoustic standing wave vibration, the maximum limit of operating noise, heat exchangers running almost no noise; " Ff="内部结构设计时考虑了<声共鸣许用准则>(Eisnger准则和Bevins准则),有效抑制了声驻波震动现象,最大限度的限制了运行噪音,换热器运行时几乎没有噪音;">Designed to take into account the internal structure of the <sound resonance allowable criteria> (Eisnger guidelines and Bevins guidelines), effectively inhibited the phenomenon of acoustic standing wave vibration, the maximum limit of operating noise, heat exchangers running almost no noise;
8, JAD heat exchanger by the ASME, ANCC and other eight international quality certification, in Europe known as the "Prince of steam."

SECESPOL JAD series of heat exchangers and plate heat exchanger more
First, the EU imported JAD series of heat exchangers:
1, JAD heat exchanger within the unique reverse spiral, spiral coil structure determines its advanced performance, the series of heat exchangers is SECESPOL International Group sets Poland Gdansk University of Technology Institute of the heat transfer technology with a number of the essence of the ASME Code in accordance with United States created a new type of shell and tube heat exchanger.
2, JAD asymmetric heat exchanger design concept has widespread applications.
3, the heat exchanger (including the shell, beam tubes and flanges) are finished stainless steel welding, corrosion resistance, long life, can be applied to a variety of fluids;
4, according to thermodynamic principles, ways to counter-current heat exchanger, coupled with its unique thread helix, effectively raising the overall heat transfer coefficient of heat exchanger, some of the heat transfer conditions, the heat transfer coefficient up to 14000W / m2 · ℃.
5, a unique internal structure of the medium enhanced the effect of turbulence, improve the overall heat transfer coefficient at the same time ensure the heat exchanger has a self-cleaning function, difficult to scale.
6, equipment, compact structure, small size, the unit supplies less heat, reducing the footprint, save infrastructure investment.
7, easy installation, no special pre-cast base, equipment can be connected directly with the pipeline, reducing installation costs.
8, easy to clean, do not post maintenance.
Second, the combination of plate heat exchanger
1, the production of varieties mostly gasket type, fewer species, 10 or so.
2, the single heat transfer area of ​​only 0.1-2.0 meters.
3, the main plate 304 stainless steel, sheet thickness 0.3-1.0mm, shorter service life.
4, the design temperature ≤ 170 ℃, the design pressure ≤ 1.6MPa.
5, small size, easy installation, small footprint.
6, for water of heat exchanger.
Third, a comprehensive comparison
1, plate heat exchanger gasket material determine its application is limited in a variety of conditions: temperature of the current general domestic gasket (critical temperature), tincture of nitrile rubber 110 ℃, 160 ℃ EPDM , fluorine rubber, 175 ℃, some of the imported rubber gasket temperature up to 265 ℃, but the price is expensive. JAD Series Tube bundle heat exchanger shell and all-stainless steel welding production, no gasket, the working pressure 1.6MPa, highest working temperature of up to 400 ℃.
2, plate heat exchanger used in high temperature and pressure of the steam - water heat conditions, the sealing gasket and easy to aging, the frequent need to remove, replace gaskets, high maintenance costs. JAD series of heat exchangers during operation itself without maintenance, cleaning is simple and low cost.
3, JAD heat exchanger at a high temperature, high pressure steam conditions, is even more evident advantages, the general board for the restrictions; for water - water heat exchanger such as symmetry conditions, the board for a more competitive advantage.
4, plate heat exchanger plate spacing is only 2-3mm, easy plug and the internal heat exchanger diversion trough structure complex, slow water flow rate of fouling tendency; and because the plate heat exchanger gasket sealing reasons, the heat exchanger fouling or clogging after chemical cleaning can not only clean the board removed the piece; in damage not only easy to disassemble and clean the sealing plate, resulting in increased cleaning costs, but also because of manual cleaning, resulting in heat exchanger plate The damage to the film surface, resulting in pitting corrosion, affecting the life of the heat exchanger.
JAD heat exchanger 100 ° connection and screw thread structure, a unique surface treatment technology and media on both sides of the countercurrent heat exchanger to achieve a high flow rate, temperature gradient is small, dirt coefficient characteristics, low fouling tendency.
Even after scaling phenomenon long-term use can also be used quickly descaling chemical cleaning methods, saving time, effort, low cost, good effect.
5, JAD series of heat exchangers integrated high heat transfer coefficient, heat transfer effect.

JAD series heat exchanger and the volume of domestic hot water heat exchanger applications in comparison
JAD series of heat exchangers for the European Union EU imported products, is SECESPOL International Group with Poland Gdansk University of Technology Institute of the heat transfer technology and a number of the essence, invented in 1988, the production of a spiral-ribbed tube heat exchanger. Products in strict accordance with American Society of Mechanical Engineers (ASME) standards for manufacturing, is the world's most advanced one shell and tube heat exchangers are widely used in chemical, thermal, food, pharmaceutical, HVAC and other industries, and its life the application of hot water heat exchanger with the ordinary compared to the volume has the following advantages:
1, JAD series of heat exchanger thermal efficiency, saving energy (steam):
Within the unique reverse winding, spiral coil structure to countercurrent heat exchanger means to make steam condensation heat transfer tube bundle can be fully, without going through the secondary heat exchanger, it can save a lot of steam;
2, JAD stainless steel heat exchanger for the whole welding, high temperature high pressure:
Because JAD heat exchanger tubes using beam and shell all stainless steel, with a uniform coefficient of expansion, the highest pressure 1.6MPa, the highest temperature 400 ℃, not due to instability caused by pressure and temperature of heat exchanger deformation; without temperature and pressure reduction devices.
The normal volume low pressure heat exchanger, high pressure required to install temperature and pressure reduction devices, not only the initial investment costs, while temperature and pressure reduction unit will result in a waste heat steam.
3, JAD series of heat exchangers compact, easy installation, small footprint
JAD series of small heat exchanger, saving infrastructure investment; light weight, easy to install, the device can be directly connected with the pipe, reducing installation costs.
General volume of heat exchanger in size, usually 3-5 times JAD, a larger area; install complex and require pre-basic, higher installation costs.
4, JAD series of heat exchangers and long service life:
SECESPOL heat exchanger using Owen (OWEN) principle of turbulence buffeting frequency standards, using the minimum clearance Tube bundle design, effectively eliminating the turbulence buffeting phenomenon, extending the life of the heat exchanger. JAD heat exchanger design life of up to 40 years, normal use conditions, the heat exchanger 8 years, the quality problem free repair or replacement.
The general volume of heat exchanger can only use about 5 years.
5, JAD series of heat exchanger fouling tendency of the low, low maintenance costs
JAD series of heat exchangers unique internal structure, a unique surface treatment technology and media on both sides of the countercurrent heat exchanger, heat transfer coefficient at the same time improve the overall heat exchanger to ensure self-cleaning function, low fouling tendency. Even after scaling phenomenon long-term use can also be used quickly descaling chemical cleaning methods, saving time, effort, low cost, good effect.
Volume of heat exchanger required to regularly check, visual inspection at least once a year, at least once every three years, internal and external inspection, maintenance workload, high maintenance costs.
6, JAD series of heat exchanger can be adjusted according to actual use of water, while the volume of heat exchanger water temperature not higher than the limit value of the terminal, otherwise it will accelerate the scaling, increase the maintenance workload.
7, JAD series of energy saving heat exchanger:
JAD series of heat exchanger tube heat medium walking, walking shell refrigerant, cold packs can maintain the flow of heat exchanger itself is dry, will not affect the ambient air.
Volume heat exchanger heat exchanger is because both the water tank, its warm, humid environment to create the conditions for the propagation of micro-organisms, can easily produce large amounts of bacteria can cause infection and inflammation, resulting in secondary indoor pollution, the threat people's health.